Hygiena's™ SystemSURE Plus is the world's best-selling ATP Sanitation Monitoring System (Hygiena's description). With improved functionality, new software, and increased memory, the SystemSURE Plus meets the demands of the cleaning and restoration companies around the world.
The Starter Kit puts the meter and your first 100 tests in one order — everything needed to start swabbing on the first job.
The price includes thermal packaging and ice pack for shipping. The UltraSnap swabs are a reagent product: put them in the fridge (2–8 °C) when the carton arrives. Hygiena allows up to 4 weeks at room temperature before use.
Not in the kit: the USB cable for downloading results and the CalCheck calibration verification device — confirm with us whether a USB cable ships with current kits before ordering one.
What Is ATP Testing?
The ATP test is a process of rapidly measuring actively growing microorganisms through the detection of adenosine triphosphate, or ATP.
ATP is a molecule found in and around living cells, and as such it gives a direct measure of biological concentration and health. ATP is quantified by measuring the light produced through its reaction with the naturally occurring firefly enzyme luciferase using a luminometer. The amount of light produced is directly proportional to the amount of ATP present in the sample.
What a reading is and is not: ATP is present in organic residue generally — food soil, body fluids, biofilm and the cells within them — not only in living microorganisms. A reading in relative light units (RLU) tells you how much organic residue is on the surface. It does not identify organisms and it is not a microbial count. Use it to verify that cleaning removed the soil; use laboratory microbiological sampling where a job needs organisms identified or counted.
Why Use ATP Testing?
With ATP testing, a restoration contractor can test the initial condition of surfaces and standing water to determine the level of contamination and thus categorize the loss more accurately as 1, 2 or 3.
The testing can also be used during the cleaning and drying processes to determine progress. And finally, at the completion of the job, testing can verify clean and sanitary materials and surfaces.
Keep the categorisation point in proportion: an ATP result is supporting evidence, not the classification itself. Water category is decided from the source of the water, how long it has been there and what it has contacted, as your restoration standard sets out. A high reading supports treating the loss as contaminated; a low reading on its own does not make a loss Category 1.
SystemSURE Plus Benefits
As listed by Hygiena:
Most cost-effective ATP hygiene monitoring system available
Provides real-time feedback and facilitates long-term data analysis
Optimizes and verifies that cleaning procedures are working
Assists in developing and improving process and risk assessment programs (ie. HACCP & GMPs)
No scheduled yearly maintenance is necessary
Available Calibration Control Kit for in-house confirmation of calibration
Complimentary SureTrend Software
SystemSURE Plus Specifications
Sensitive - can detect down to 1 femtomole (1 x 10-15 moles) of ATP
Advanced photodiode sensor offers low variation and stays in calibration
Calibration self-check at start up with optional full diagnostic check mode
The symbol keypad is easy for any user to understand and navigate
Powered by 2 x AA batteries for several months of uninterrupted use
Memory capacity:
100 programmable test plans
200 programmable user IDs
251 programmable locations per test plan
5,000 programmable test locations
Small, lightweight, handheld instrument (0.57 lbs., 7.6 x 17.8 x 3 cm)
Quick-test mode enables ad-hoc testing
Large viewable screen with back-light and optional bold text
Removable read chamber for easy cleaning
Connects to SureTrend software via USB
At a Glance
Kit
Hygiena SystemSURE Plus Starter Kit
SKU
HGBKIT-100
Meter
SystemSURE Plus (SS3), photodiode sensor, 2 × AA batteries
Tests included
100 × UltraSnap surface ATP (US2020)
Result time
About 15 seconds (Hygiena)
Meter size / weight
7.6 × 17.8 × 3 cm; 0.57 lb (about 260 g)
Swab storage
2–8 °C; up to 4 weeks at room temperature (Hygiena UltraSnap instructions)
Shipping
Thermal packaging and ice pack included in the price
Warranty
Not published by Hygiena — ask us
Which Tests It Reads
Hygiena lists the SystemSURE Plus as compatible with its UltraSnap surface ATP test and AquaSnap water ATP test, and with its other luminometer-read test devices. The Hygiena tests we carry:
The PRO-Clean and SpotCheck Plus tests are colour-change tests read by eye — they do not need the meter.
Third-party swabs: Anaeron lists its CleanTrust ATP Surface Swab as compatible with the SystemSURE Plus. Hygiena lists only its own tests. If you mix brands, set a separate baseline and limits for each swab type — RLU figures from different swab chemistries are not interchangeable.
Using It Well
Let the tests warm up. Hygiena's UltraSnap instructions call for the device to reach 21–25 °C before testing. A swab straight from the fridge reads low.
Swab the same way every time. A 10 × 10 cm area in a criss-cross pattern is Hygiena's standard for flat surfaces. Results are only comparable when the sampling is.
Read promptly. Insert the activated swab within 30 seconds (UltraSnap instructions). The SystemSURE Plus gives the result in about 15 seconds.
Set your own limits. The meter supports programmable pass, caution and fail limits. Build them from readings on surfaces you know are properly cleaned, not from a number copied from someone else's procedure.
Sanitiser still on the surface can suppress the reading. Sample after cleaning and before sanitising, or allow for it in your procedure.
Calibration and Data
The meter runs a sensor self-check at start-up. For in-house confirmation between checks, Hygiena's reusable CalCheck replaces the older PCD4000 Calibration Control Kit. A CalCheck verifies the meter; it does not adjust it — a failed check means contact us.
Results transfer to Hygiena's SureTrend software over USB using the SystemSURE Plus USB cable. Hygiena now also offers SureTrend as a cloud platform; confirm with us which version and licence applies before you build a reporting system around it.
Frequently Asked Questions
How many jobs will 100 swabs cover?
That depends on your sampling plan. A restoration job typically needs readings before, during and after work at each location you intend to report on. Work out swabs per job first, then reorder 100 packs or the 2,000 pack.
Do the swabs expire?
Yes. Each pack carries an expiry date and should not be used beyond it. Shelf life depends on refrigerated storage — see the Hygiena storage and shelf life guide (PDF).
Can the meter tell me whether mould or bacteria are present?
No. It measures ATP from organic residue generally. It verifies cleaning; it does not identify organisms.
Setting up ATP testing for restoration sign-off? Tell us what you need to demonstrate and to whom, and we will help you choose the meter, tests and sampling routine.
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Estimate shipping
Refund Policy
Cancellation and Returns Policy
Unless otherwise stated in the product description, The Moisture Meter Company allows the return of products for 7 days from delivery in the following cases:
physical damage to the product
the product is defective **(where no warranty is offered by the original manufacturer)
the product is significantly different from the description (wrong size, colour, quality or material related issues)
Unless otherwise stated in the product description the product must be in its original condition. Only unused, unaltered, not soiled products will be accepted, brand packaging should be intact, replacements will be made if the product is available within a reasonable time.
To return a product, you can raise a return request at by calling us on 1800 68 68 69 or by email at info@moisturemeters.com.au, and by providing the following details: Name and contact details, date of purchase, invoice number or order ID, images clearly demonstrating damage, or a description of the defect or missing and incomplete product.
After receiving your request The Moisture Meter Company will confirm the return request and will inform you about the pickup process. Please ensure that the product is in unused and original condition. Include all labels, original packing, and invoice along with the product.
** Original Manufactures Warranty
Faulty products and manufacturing defects in most cases are warranted by the original manufacturer of the product. Call or email to determine if your product is covered under warranty. Post receiving your request The Moisture Meter Company will confirm your request and will inform you about the warranty process.