Description
Stop guessing. Start measuring.
If you're serious about restoration, hygiene and compliance work, you need more than visual inspection.
The CleanTrust™ Touch™ YZ3500 Luminometer gives you fast, measurable evidence of cleanliness, detecting ATP contamination on surfaces and in water with a 10-second reading.
Paired with CleanTrust ATP swabs, this unit becomes the central tool for verifying cleaning effectiveness and contamination risk on site. CleanTrust is a brand of Anaeron Pty Ltd, Frenchs Forest NSW.
Why This Matters on the Job
- Prove your work to clients and insurers. Replace "it looks clean" with measurable data.
- Make better decisions on site. Identify contamination straight away and act immediately.
- Reduce call-backs and disputes. Back up your results with recorded evidence.
- Win higher-value commercial and insurance work. Professional testing = higher credibility.
Key Benefits
- Instant ATP detection (results in seconds). No waiting days for a lab to report ATP — you get an answer on site. ATP is a hygiene indicator, not a mould or bacteria count; see the FAQs.
- High-sensitivity measurement. A photodiode detector with single-photon counting detects even low contamination levels (1 × 10⁻¹⁶ mol ATP, Anaeron).
- Simple touchscreen operation. The 5.5 in (14 cm) Android-based interface makes it easy for any technician to use.
- Data logging and reporting capability. Store and analyse results for QA, compliance and reporting.
- Wireless connectivity (WiFi / Bluetooth / USB-C). Transfer data easily across devices and systems.
- Works with surface and water ATP swabs. Covers both environmental and water contamination testing with CleanTrust ATP Surface Swabs and CleanTrust ATP Water Total Swabs.
Ideal For
- Water damage restorers verifying post-clean contamination levels
- Mould remediation projects requiring clearance validation
- Contractors working on insurance or compliance-driven jobs
- Commercial cleaners implementing QA programs
- HVAC cleaning where biofilm or contamination is suspected
How It Works
- Swab the surface or water sample.
- Insert the swab into the luminometer.
- Run the test (≈10 seconds).
- Get an RLU reading (contamination level).
Higher reading = higher contamination: clean again before sign-off.
In more detail, from Anaeron's YZ3500 user manual:
- Turn the meter on. If it has come from a hot van or a cold site, let it sit for 10–20 minutes so it is close to room temperature.
- Stand it on its rear support on a flat surface, or hold it with less than 45° of tilt. A built-in gyroscope warns you if it tilts too far during a test.
- Swab a 10 × 10 cm area, horizontally and vertically, return the swab to its tube, break the valve, squeeze the bulb to release the liquid and shake.
- Open the chamber cover, insert the swab vertically and close the cover. The test starts automatically.
- Read the result, then remove the swab straight away. Re-testing an old swab gives unreliable readings.
Pass, Caution and Fail Thresholds
Each result is judged against a minimum and maximum RLU value you set. Below the minimum is a pass, between the two is caution, and above the maximum is a fail. Anaeron quotes a default threshold of 20–60 RLU for the meter. Anaeron's ATP surface swab instructions suggest different default limits (under 10 pass, 10–30 warning, over 30 fail), so decide your own limits and set them in the meter before you rely on the colour-coded result.
Thresholds can be saved per test location, so a kitchen bench and a subfloor can carry different limits.
Technical Specifications
| Brand / model | CleanTrust™ Touch™ YZ3500 (Anaeron Pty Ltd) |
|---|---|
| Our SKU | CTYZ3500 |
| Test time | ~10 seconds per reading |
| Detection range | 0–32,000 RLU |
| Sensitivity | Down to 1 × 10⁻¹⁶ mol ATP |
| Detector | Photodiode, single-photon counting |
| Sensors | Gyroscope (tilt warning), chamber cover switch, swab detection |
| Swab length | 17 cm CleanTrust swabs |
| Display | 5.5 in (14 cm) touchscreen (Android OS) |
| Data storage | Up to 10 million records (50 GB, expandable by SD card) |
| Connectivity | WiFi, Bluetooth, USB-C |
| Battery | Rechargeable lithium, 3.7 V 3500 mAh, removable (IEC 62133-2) |
| Tests per charge | Up to ~3000 tests per charge (our listing and the Anaeron website); the Anaeron user manual states 2500 samples of continuous detection |
| Standby | 20 days (user manual); 15 days (Anaeron flyer) |
| Dimensions | 190 × 82 × 34 mm |
| Weight | 400 g |
| Certification (manufacturer) | CE, RoHS |
| Warranty | 2 years |
Recording and Reporting
- Locations: name each test point and give it its own thresholds.
- Plans: group locations into a test plan with reminders, so every point on a job gets tested.
- Inspectors: log which technician ran each test, with optional passwords.
- History: filter results by pass, caution and fail, by inspector, location, plan and date, and view trends by day.
- Export: results export as a spreadsheet file over USB-C, or sync to Anaeron's PC analysis software (WiFi or USB) or its cloud platform.
Deleting records can be password-protected. The manual's initial management password is 123456, so set your own before the meter goes on a job.
Calibration
The meter has an automatic calibration function. Anaeron also provides a calibration check routine (internal LED, negative and positive tests) that needs its calibration quality control tube. That tube is not currently listed by us; contact us if your QA program requires documented calibration checks.
Care and Battery
- Keep the chamber cover closed when not testing, and keep the chamber out of strong light.
- Never let liquid into the chamber. If the meter gets wet, do not turn it on; remove the battery.
- Clean the case with a damp cloth or neutral detergent. Keep solvents, grease and corrosive products off the meter.
- Charge only with the supplied adapter and unplug when full. Charge at least monthly in storage, and run a full charge-discharge cycle every three months.
- Anaeron's manual says to remove the lithium battery when transporting the instrument.
Why Professionals Use a Luminometer
Without ATP testing:
- You're relying on visual inspection
- Contamination can go undetected
- Results are hard to defend
With a luminometer:
- You get objective, measurable evidence
- Your process becomes repeatable and professional
- You can justify your work and pricing with data
This is what separates basic cleaning from professional restoration and hygiene verification.
Part of a Complete Testing System
The YZ3500 is the core of a contamination verification system:
- Protein swabs — identify organic contamination (read by eye, not in the meter)
- ATP swabs (surface) — verify cleaning effectiveness
- ATP swabs (water) — assess water contamination
- Incubator — improves consistency where required (used with the Allergen protein swab; ATP swabs need no incubation)
Together, this creates a full QA and reporting workflow.
Pro Tip
Set internal pass/fail RLU thresholds for your business. This standardises results across technicians and makes your reporting far more defensible.
Common Mistakes This Helps Avoid
- Relying on visual cleanliness alone
- Missing contamination in critical areas
- Inconsistent results between technicians
- Failing hygiene audits or insurance requirements
- Not having evidence when a job is questioned
Frequently Asked Questions
Which swabs does it read?
Anaeron lists CleanTrust ATP Surface Swabs and CleanTrust TOTAL ATP Water Swabs, and the manual says to use only matching swabs. Protein swabs are read by eye.
Does a low RLU mean the surface is free of mould or bacteria?
No. ATP measures organic residue from living and once-living material. It is a fast hygiene indicator, not a count or identification of mould or bacteria, and it does not replace laboratory sampling where a clearance specification calls for it.
How many tests will I get from a charge?
Anaeron's website and our listing quote about 3000; the user manual says 2500. Plan on the lower figure for a long day and charge overnight.
What RLU limit should I use?
There is no single restoration standard. The meter ships with Anaeron's default (20–60 RLU) and the swab instructions suggest tighter limits. Pick limits that suit your work, set them per location and apply them consistently.
How do I get results into my report?
Export from History to a spreadsheet file over USB-C, or sync to Anaeron's PC analysis software or cloud platform.
What is the warranty?
2 years. Your rights under Australian Consumer Law apply in addition; see below.
Turn Your Cleaning into Measurable Results
Add the CleanTrust YZ3500 to your workflow and start delivering data-backed cleaning, not guesswork.
Documents
CleanTrust™ Touch™ YZ3500 Luminometer Flyer
CleanTrust™ Touch™ YZ3500 Luminometer Manual
Video
Related Products
- CleanTrust ATP Surface Swab, Box of 100
- CleanTrust ATP Water Total Swab, Box of 100
- CleanTrust Surface Protein Swab, Box of 100
- CleanTrust Protein Allergen Swab, Box of 100
- CleanTrust Incubator – Small Dry Bath
Your rights under Australian law
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
These rights apply in addition to the manufacturer’s warranty set out above and are not limited by it. Contact The Moisture Meter Company first and we will handle the claim from this end.
Setting up ATP testing for the first time, or not sure what thresholds to use? Contact The Moisture Meter Company before ordering and we will help you choose the meter and swabs for your work.
Estimate shipping
Refund Policy
Refund Policy
At The Moisture Meter Company (TMMC), a division of Carpet Cleaners Warehouse, we are committed to complying with the Australian Consumer Law (ACL) and providing fair outcomes for our customers.
Australian Consumer Law
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement, repair, or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if they fail to be of acceptable quality and the failure does not amount to a major failure.
Damaged, Faulty or Incorrect Goods
If you receive a product that is damaged in transit, faulty, defective, or incorrectly supplied, please contact us as soon as possible.
To assist with assessment, we may request photographs, serial numbers, proof of purchase, or other information relevant to the claim.
Where a product is confirmed to be faulty, damaged, incorrectly supplied, or otherwise covered under Australian Consumer Law, TMMC will provide an appropriate remedy, which may include:
- Repair
- Replacement
- Store credit
- Refund
TMMC will cover reasonable return shipping costs for approved warranty, fault, damage, or incorrect supply claims.
Change of Mind Returns
TMMC may, at its sole discretion, accept returns for change of mind within 14 days of delivery, provided that:
- The return is approved by TMMC before being sent back.
- The product is unused and in original condition.
- The product is returned in its original packaging.
- All accessories, manuals, and included items are returned.
- The product is not a special order, made-to-order, clearance, consumable, or non-returnable item.
Approved change of mind returns may be subject to a restocking fee and the customer is responsible for all return shipping costs.
Original freight charges are non-refundable unless required under Australian Consumer Law.
Non-Returnable Items
Unless required under Australian Consumer Law, the following items cannot be returned for change of mind:
- Special order products
- Made-to-order products
- Hygiena swabs, test reagents and other consumables
- Probes, electrodes and pins that have been used
- Products specifically marked as non-returnable
- Clearance or end-of-line items
Return Process
Before returning any product, customers must obtain return authorisation from TMMC.
Please contact us using one of the methods below:
- Phone: 1800 68 68 69
- Email: info@moisturemeters.com.au
Returns sent without prior approval may be refused or delayed.
Refund Processing
Approved refunds will be processed to the original payment method used for the purchase unless otherwise agreed.
Refunds are generally processed after the returned product has been received, inspected, and approved.
Processing times may vary depending on the payment provider.
Warranty Claims
Many products sold by TMMC are also covered by manufacturer warranties. These are in addition to your rights under the Australian Consumer Law.
Warranty claims may require inspection, testing, repair, replacement, or manufacturer assessment before a final outcome is determined.
Equipment must be returned to TMMC in Queensland for warranty assessment. The customer pays freight to return the item; if a covered fault is confirmed, TMMC reimburses that freight and pays return freight. If the fault is not covered, we will provide a written quote before any work is done.
Business Customers
Nothing in this policy excludes, restricts, or modifies any rights available under Australian Consumer Law.
Where permitted by law, remedies available for goods supplied for business use may be limited in accordance with applicable legislation.
Contact Us
The Moisture Meter Company
Phone: 1800 68 68 69
Email: info@moisturemeters.com.au
Queensland
D1-3/194 Zillmere Road, Boondall QLD 4034
Victoria
Unit 1/5 Gatwick Road, Bayswater North VIC 3153
This policy was last updated on 18 November 2026.