{"product_id":"cleantrust-touch-yz3500-luminometer","title":"CleanTrust™ Touch™ YZ3500 Luminometer","description":"\u003cp\u003eStop guessing. Start measuring.\u003c\/p\u003e\n\u003cp\u003eIf you're serious about restoration, hygiene and compliance work, you need more than visual inspection.\u003c\/p\u003e\n\u003cp\u003eThe CleanTrust™ Touch™ YZ3500 Luminometer gives you fast, measurable evidence of cleanliness, detecting ATP contamination on surfaces and in water with a 10-second reading.\u003c\/p\u003e\n\u003cp\u003ePaired with CleanTrust ATP swabs, this unit becomes the central tool for verifying cleaning effectiveness and contamination risk on site. CleanTrust is a brand of Anaeron Pty Ltd, Frenchs Forest NSW.\u003c\/p\u003e\n\u003ch2\u003eWhy This Matters on the Job\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProve your work to clients and insurers. Replace \"it looks clean\" with measurable data.\u003c\/li\u003e\n\u003cli\u003eMake better decisions on site. Identify contamination straight away and act immediately.\u003c\/li\u003e\n\u003cli\u003eReduce call-backs and disputes. Back up your results with recorded evidence.\u003c\/li\u003e\n\u003cli\u003eWin higher-value commercial and insurance work. Professional testing = higher credibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstant ATP detection (results in seconds). No waiting days for a lab to report ATP — you get an answer on site. ATP is a hygiene indicator, not a mould or bacteria count; see the FAQs.\u003c\/li\u003e\n\u003cli\u003eHigh-sensitivity measurement. A photodiode detector with single-photon counting detects even low contamination levels (1 × 10⁻¹⁶ mol ATP, Anaeron).\u003c\/li\u003e\n\u003cli\u003eSimple touchscreen operation. The 5.5 in (14 cm) Android-based interface makes it easy for any technician to use.\u003c\/li\u003e\n\u003cli\u003eData logging and reporting capability. Store and analyse results for QA, compliance and reporting.\u003c\/li\u003e\n\u003cli\u003eWireless connectivity (WiFi \/ Bluetooth \/ USB-C). Transfer data easily across devices and systems.\u003c\/li\u003e\n\u003cli\u003eWorks with surface and water ATP swabs. Covers both environmental and water contamination testing with \u003ca href=\"\/products\/cleantrust-atp-surface-swab-box-of-100\"\u003eCleanTrust ATP Surface Swabs\u003c\/a\u003e and \u003ca href=\"\/products\/cleantrust-atp-water-total-swab-box-of-100\"\u003eCleanTrust ATP Water Total Swabs\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater damage restorers verifying post-clean contamination levels\u003c\/li\u003e\n\u003cli\u003eMould remediation projects requiring clearance validation\u003c\/li\u003e\n\u003cli\u003eContractors working on insurance or compliance-driven jobs\u003c\/li\u003e\n\u003cli\u003eCommercial cleaners implementing QA programs\u003c\/li\u003e\n\u003cli\u003eHVAC cleaning where biofilm or contamination is suspected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eSwab the surface or water sample.\u003c\/li\u003e\n\u003cli\u003eInsert the swab into the luminometer.\u003c\/li\u003e\n\u003cli\u003eRun the test (≈10 seconds).\u003c\/li\u003e\n\u003cli\u003eGet an RLU reading (contamination level).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eHigher reading = higher contamination: clean again before sign-off.\u003c\/p\u003e\n\u003cp\u003eIn more detail, from Anaeron's YZ3500 user manual:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTurn the meter on. If it has come from a hot van or a cold site, let it sit for 10–20 minutes so it is close to room temperature.\u003c\/li\u003e\n\u003cli\u003eStand it on its rear support on a flat surface, or hold it with less than 45° of tilt. A built-in gyroscope warns you if it tilts too far during a test.\u003c\/li\u003e\n\u003cli\u003eSwab a 10 × 10 cm area, horizontally and vertically, return the swab to its tube, break the valve, squeeze the bulb to release the liquid and shake.\u003c\/li\u003e\n\u003cli\u003eOpen the chamber cover, insert the swab vertically and close the cover. The test starts automatically.\u003c\/li\u003e\n\u003cli\u003eRead the result, then remove the swab straight away. Re-testing an old swab gives unreliable readings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003ePass, Caution and Fail Thresholds\u003c\/h2\u003e\n\u003cp\u003eEach result is judged against a minimum and maximum RLU value you set. Below the minimum is a pass, between the two is caution, and above the maximum is a fail. Anaeron quotes a default threshold of 20–60 RLU for the meter. Anaeron's ATP surface swab instructions suggest different default limits (under 10 pass, 10–30 warning, over 30 fail), so decide your own limits and set them in the meter before you rely on the colour-coded result.\u003c\/p\u003e\n\u003cp\u003eThresholds can be saved per test location, so a kitchen bench and a subfloor can carry different limits.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand \/ model\u003c\/th\u003e\n\u003ctd\u003eCleanTrust™ Touch™ YZ3500 (Anaeron Pty Ltd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOur SKU\u003c\/th\u003e\n\u003ctd\u003eCTYZ3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTest time\u003c\/th\u003e\n\u003ctd\u003e~10 seconds per reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetection range\u003c\/th\u003e\n\u003ctd\u003e0–32,000 RLU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003eDown to 1 × 10⁻¹⁶ mol ATP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetector\u003c\/th\u003e\n\u003ctd\u003ePhotodiode, single-photon counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eGyroscope (tilt warning), chamber cover switch, swab detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSwab length\u003c\/th\u003e\n\u003ctd\u003e17 cm CleanTrust swabs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5.5 in (14 cm) touchscreen (Android OS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData storage\u003c\/th\u003e\n\u003ctd\u003eUp to 10 million records (50 GB, expandable by SD card)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eWiFi, Bluetooth, USB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery\u003c\/th\u003e\n\u003ctd\u003eRechargeable lithium, 3.7 V 3500 mAh, removable (IEC 62133-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTests per charge\u003c\/th\u003e\n\u003ctd\u003eUp to ~3000 tests per charge (our listing and the Anaeron website); the Anaeron user manual states 2500 samples of continuous detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandby\u003c\/th\u003e\n\u003ctd\u003e20 days (user manual); 15 days (Anaeron flyer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e190 × 82 × 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e400 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification (manufacturer)\u003c\/th\u003e\n\u003ctd\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eRecording and Reporting\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLocations: name each test point and give it its own thresholds.\u003c\/li\u003e\n\u003cli\u003ePlans: group locations into a test plan with reminders, so every point on a job gets tested.\u003c\/li\u003e\n\u003cli\u003eInspectors: log which technician ran each test, with optional passwords.\u003c\/li\u003e\n\u003cli\u003eHistory: filter results by pass, caution and fail, by inspector, location, plan and date, and view trends by day.\u003c\/li\u003e\n\u003cli\u003eExport: results export as a spreadsheet file over USB-C, or sync to Anaeron's PC analysis software (WiFi or USB) or its cloud platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDeleting records can be password-protected. The manual's initial management password is 123456, so set your own before the meter goes on a job.\u003c\/p\u003e\n\u003ch2\u003eCalibration\u003c\/h2\u003e\n\u003cp\u003eThe meter has an automatic calibration function. Anaeron also provides a calibration check routine (internal LED, negative and positive tests) that needs its calibration quality control tube. That tube is not currently listed by us; contact us if your QA program requires documented calibration checks.\u003c\/p\u003e\n\u003ch2\u003eCare and Battery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eKeep the chamber cover closed when not testing, and keep the chamber out of strong light.\u003c\/li\u003e\n\u003cli\u003eNever let liquid into the chamber. If the meter gets wet, do not turn it on; remove the battery.\u003c\/li\u003e\n\u003cli\u003eClean the case with a damp cloth or neutral detergent. Keep solvents, grease and corrosive products off the meter.\u003c\/li\u003e\n\u003cli\u003eCharge only with the supplied adapter and unplug when full. Charge at least monthly in storage, and run a full charge-discharge cycle every three months.\u003c\/li\u003e\n\u003cli\u003eAnaeron's manual says to remove the lithium battery when transporting the instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Professionals Use a Luminometer\u003c\/h2\u003e\n\u003cp\u003eWithout ATP testing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou're relying on visual inspection\u003c\/li\u003e\n\u003cli\u003eContamination can go undetected\u003c\/li\u003e\n\u003cli\u003eResults are hard to defend\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith a luminometer:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou get objective, measurable evidence\u003c\/li\u003e\n\u003cli\u003eYour process becomes repeatable and professional\u003c\/li\u003e\n\u003cli\u003eYou can justify your work and pricing with data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is what separates basic cleaning from professional restoration and hygiene verification.\u003c\/p\u003e\n\u003ch2\u003ePart of a Complete Testing System\u003c\/h2\u003e\n\u003cp\u003eThe YZ3500 is the core of a contamination verification system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/cleantrust-surface-protein-swab-box-of-100\"\u003eProtein swabs\u003c\/a\u003e — identify organic contamination (read by eye, not in the meter)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/cleantrust-atp-surface-swab-box-of-100\"\u003eATP swabs (surface)\u003c\/a\u003e — verify cleaning effectiveness\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/cleantrust-atp-water-total-swab-box-of-100\"\u003eATP swabs (water)\u003c\/a\u003e — assess water contamination\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/cleantrust-incubator-small-dry-bath\"\u003eIncubator\u003c\/a\u003e — improves consistency where required (used with the \u003ca href=\"\/products\/cleantrust-protein-allergen-swab-box-of-100\"\u003eAllergen protein swab\u003c\/a\u003e; ATP swabs need no incubation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTogether, this creates a full QA and reporting workflow.\u003c\/p\u003e\n\u003ch2\u003ePro Tip\u003c\/h2\u003e\n\u003cp\u003eSet internal pass\/fail RLU thresholds for your business. This standardises results across technicians and makes your reporting far more defensible.\u003c\/p\u003e\n\u003ch2\u003eCommon Mistakes This Helps Avoid\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRelying on visual cleanliness alone\u003c\/li\u003e\n\u003cli\u003eMissing contamination in critical areas\u003c\/li\u003e\n\u003cli\u003eInconsistent results between technicians\u003c\/li\u003e\n\u003cli\u003eFailing hygiene audits or insurance requirements\u003c\/li\u003e\n\u003cli\u003eNot having evidence when a job is questioned\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich swabs does it read?\u003c\/h3\u003e\n\u003cp\u003eAnaeron lists CleanTrust ATP Surface Swabs and CleanTrust TOTAL ATP Water Swabs, and the manual says to use only matching swabs. Protein swabs are read by eye.\u003c\/p\u003e\n\u003ch3\u003eDoes a low RLU mean the surface is free of mould or bacteria?\u003c\/h3\u003e\n\u003cp\u003eNo. ATP measures organic residue from living and once-living material. It is a fast hygiene indicator, not a count or identification of mould or bacteria, and it does not replace laboratory sampling where a clearance specification calls for it.\u003c\/p\u003e\n\u003ch3\u003eHow many tests will I get from a charge?\u003c\/h3\u003e\n\u003cp\u003eAnaeron's website and our listing quote about 3000; the user manual says 2500. Plan on the lower figure for a long day and charge overnight.\u003c\/p\u003e\n\u003ch3\u003eWhat RLU limit should I use?\u003c\/h3\u003e\n\u003cp\u003eThere is no single restoration standard. The meter ships with Anaeron's default (20–60 RLU) and the swab instructions suggest tighter limits. Pick limits that suit your work, set them per location and apply them consistently.\u003c\/p\u003e\n\u003ch3\u003eHow do I get results into my report?\u003c\/h3\u003e\n\u003cp\u003eExport from History to a spreadsheet file over USB-C, or sync to Anaeron's PC analysis software or cloud platform.\u003c\/p\u003e\n\u003ch3\u003eWhat is the warranty?\u003c\/h3\u003e\n\u003cp\u003e2 years. Your rights under Australian Consumer Law apply in addition; see below.\u003c\/p\u003e\n\u003ch2\u003eTurn Your Cleaning into Measurable Results\u003c\/h2\u003e\n\u003cp\u003eAdd the CleanTrust YZ3500 to your workflow and start delivering data-backed cleaning, not guesswork.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0526\/7462\/5732\/files\/CleanTrust-Touch-Flyer_V1.3_July-2025.pdf\" target=\"_blank\"\u003eCleanTrust™ Touch™ YZ3500 Luminometer Flyer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0526\/7462\/5732\/files\/YZ3500_Luminometer_Manual_-Anaeron_Ver._2025-A2.pdf\" rel=\"noopener\" target=\"_blank\"\u003eCleanTrust™ Touch™ YZ3500 Luminometer Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe title=\"Find out more about CleanTrust® at www.anaeron.com.au #healthandsafety #healthandsafetyatwork\" src=\"https:\/\/www.youtube.com\/embed\/NEoVB7BTV4I\" height=\"815\" width=\"458\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/cleantrust-atp-surface-swab-box-of-100\"\u003eCleanTrust ATP Surface Swab, Box of 100\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/cleantrust-atp-water-total-swab-box-of-100\"\u003eCleanTrust ATP Water Total Swab, Box of 100\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/cleantrust-surface-protein-swab-box-of-100\"\u003eCleanTrust Surface Protein Swab, Box of 100\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/cleantrust-protein-allergen-swab-box-of-100\"\u003eCleanTrust Protein Allergen Swab, Box of 100\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/cleantrust-incubator-small-dry-bath\"\u003eCleanTrust Incubator – Small Dry Bath\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eYour rights under Australian law\u003c\/h3\u003e\n\u003cp\u003eOur goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.\u003c\/p\u003e\n\u003cp\u003eThese rights apply in addition to the manufacturer’s warranty set out above and are not limited by it. Contact The Moisture Meter Company first and we will handle the claim from this end.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eSetting up ATP testing for the first time, or not sure what thresholds to use? Contact The Moisture Meter Company before ordering and we will help you choose the meter and swabs for your work.\u003c\/p\u003e","brand":"CleanTrust™","offers":[{"title":"EACH","offer_id":47098641678532,"sku":"CTYZ3500","price":5291.49,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/7462\/5732\/files\/CTYZ3500.png?v=1792732019","url":"https:\/\/moisturemeters.com.au\/products\/cleantrust-touch-yz3500-luminometer","provider":"The Moisture Meter Company","version":"1.0","type":"link"}